This 10.1-inch TFT LCD module fills a genuine supply gap in the industrial display market: high pixel density + proven LVDS interface + extreme environmental tolerance, all in one validated design.
Here's what makes it rare:
Specification | PV101057W0245Z1-CO | Market Typical (10.1") | Rarity |
Resolution | 1920 × 1200 (WUXGA) | 1280 × 800 (WXGA) | ★★★ Fewer than 5 suppliers globally offer this combo |
Interface | Dual-LVDS 8-bit | Mostly MIPI / eDP | ★★★ LVDS at WUXGA is exceptionally rare |
Brightness | 1250 cd/m² | 350–500 cd/m² | ★★ Sunlight-readable industrial grade |
Operating Temp | -30°C ~ +80°C | -20°C ~ +70°C | ★★ Genuine wide-temperature, not just "extended" |
Optical Bonding | Yes (CO suffix) | Optional / not standard | ★ Eliminates internal reflection & fogging |
Color Depth | 16.7M (8-bit true) | 16.2M (6-bit+FRC) | ★ True 8-bit for medical/industrial accuracy |
Diagonal Size: 10.1 inch (16:10)
Active Area: 216.576 (W) × 135.36 (H) mm
Resolution: 1920 (RGB) × 1200 pixels (WUXGA)
Display Mode: IPS / Transmissive / Normally Black
Viewing Angle: 85/85/85/85 (Full Viewing Angle)
Color Depth: 16.7M (8-bit)
Contrast Ratio: 1000:1 (Typ.)
Brightness: 1250 cd/m² (Typ.)(Up to 1500nits)

Interface: Dual-LVDS (8-bit)
Pin Count: 45 Pins
Outline Dimension: 254.96 × 172.6 × 7.5 mm (Typ.)
LCM Dimension: 229.46 × 149.10 × 4.8 mm (Typ.)
Optical Bonding: LCD + Cover Lens fully bonded
Operating Temperature: -30°C ~ +80°C
Storage Temperature: -40°C ~ +85°C
RoHS Compliant: Yes
Backlight Lifetime: 50,000+ hours (Typ.)
Designed for 24/7 continuous operation
The market shift toward MIPI and eDP interfaces has left a growing number of industrial designs stranded. Many legacy HMI systems, medical instruments, and outdoor equipment were architected around LVDS, and redesigning the mainboard to accommodate MIPI/eDP carries significant re-certification costs.
The PV101057W0245Z1-CO solves this directly:
No board redesign needed
drop-in compatible with Dual-LVDS backplanes. No signal integrity concerns
LVDS differential signaling is proven in electrically noisy industrial environments.
No compromise on resolution
WUXGA at 224 PPI renders engineering schematics, patient vitals, and GIS terrain maps with zero pixelation.

Why it fits:
1250 nits + optical bonding = clear UI under direct midday sun. -30°C cold-start capability for Nordic/North American winters. 24/7 rated backlight for always-on operation.
Why it fits:
Optical bonding eliminates internal fogging in high-humidity saltwater environments. 1000:1 contrast ratio preserves chart detail against glare. Wide temperature covers arctic to tropical deployments.
Why it fits:
1920×1200 resolution at 10.1" delivers the pixel density required for CAD drawings, utility grid maps, and GIS overlays. Slim 7.5mm profile fits compact enclosures.
Why it fits:
True 8-bit 16.7M color depth ensures accurate waveform rendering. Optical bonding creates a seamless, disinfectable surface. Long-term supply commitment eliminates mid-lifecycle requalification risk.
Why it fits:
-30~+80°C range survives unheated tractor cabins and sun-baked excavator cabs. LVDS interface resists EMI from nearby motor drives and hydraulic controllers.

99.8% First-Pass Yield:
Our production line delivers a defect rate of just 2,000 PPM — versus the 3,000 PPM industry average for industrial TFT modules.
ISO 9001 / ISO 14001 / IATF 16949 Certified:
Manufacturing processes meet the most stringent quality management standards across automotive, medical, and industrial supply chains.
Loog-Term Supply Commitment:
Unlike broker-sourced panels that disappear in 12 months, KINGTECH guarantees sustained availability. If your product has a 7–10 year lifecycle, our supply chain matches it.

We understand that a standard datasheet rarely fits your exact need. Supported customization options include:
Cover Lens:
Custom glass shape, thickness, silk-screen printing, and AG/AR/AF surface treatments
FPC Design:
Tailored length, pin assignment, and stiffener configuration
Touch Panel:
PCAP with gesture support, glove operation, and water rejection firmware
Brightness Tuning:
Up to 1500 nits available for extreme outdoor applications
Interface Adaptation:
HDMI, V-by-One, or eDP converter boards upon request
If you are designing or sourcing for any of the applications above — and you've been frustrated by the lack of WUXGA + LVDS + wide-temperature options — the PV101057W0245Z1-CO was built for your use case.
Request a datasheet
Full 24-page specification with optical curves, reliability test data, and mechanical drawings.
Order an engineering sample
Evaluate optical bonding quality and LVDS signal integrity on your own bench.
Schedule a technical call
Our engineering team can review your mechanical constraints and interface requirements before you commit.
Email: helen@kingtechlcd.com
Website: www.kingtechlcd.com
Established: 2003 | Shenzhen, China
Q: Is the 1920×1200 resolution native, or scaled from a lower resolution panel?
A: Native. The panel uses a genuine 1920×RGB×1200 pixel array. Each pixel is individually addressable — there is no interpolation or scaling.
Q: Why choose LVDS over MIPI or eDP?
A: LVDS remains the dominant interface for industrial and medical equipment with product lifecycles exceeding 5 years. It offers superior EMI immunity in electrically noisy environments (motor drives, power inverters, RF equipment), and it avoids the costly mainboard redesign and EMC recertification that switching to MIPI/eDP would require.
Q: What is the MOQ for samples?
A: Engineering samples are available at 1–5 pcs for evaluation. Mass production MOQ is negotiable based on your annual forecast.
Q: Can you guarantee supply for 5+ years?
A: Yes. As an authorized Innolux distributor, KINGTECH maintains buffer stock of key panel models and provides formal long-term supply agreements. Many of our medical and industrial customers have relied on the same KINGTECH module for 7–10 years without requalification.
Q: Does the optical bonding affect repairability?
A: Our optical bonding process uses a reworkable adhesive system. While bonded modules are designed for permanent installation, field rework procedures are documented for qualified service centers.
Q: Is the touch panel included by default?
A: The PV101057W0245Z1-CO (CO suffix) includes the cover lens with optical bonding. Capacitive touch (PCAP) can be integrated upon request with your choice of controller IC and firmware configuration.